Typical
Wind Gen Application1.
This is a typical wind generator or altenator application system which
shows the connection of the dual instrument DPM62VA
which is shown monitoring the generator voltage and the battery charge
and discharge current. The maximum supply to the instrument is 28volts
at <4mA.
The instrument can measure higher voltages when using the connections
shown. The current measurement is acheived using the calibrated shunt
as fitted. The shunt MUST then be rated at the maximum load current for
use. The shunt rating may be made greater than maximum current generated
and can be provided.See the BASIC4
applications pages for further information. |